Features:
Automatic Mode
Measure Review
10 Lens Database
Calculated Lens Results
Comparative IO L Review
Sonomed Escalon AccuracyA combination of high frequency, low noiseprobes and proprietary algorithms enablesscan capture immediately upon applanation along the visual axis with precise measurement of corneal thickness, AC D, lens thickness, andaxial length.
Sonomed Escalon Usability Intuitive interface, customized set-up, precise algorithms, and advanced hardware designs enable quick and easy examination of different eye types. Sonomed Escalon ReliabilityConsistent and accurate results, time after time, year after year, we build unparalleledquality into every ultrasound system. Sonomed Escalon is still supporting instruments manufactured
over 20 years ago.
1. General: Models: 300A+ A-Scan Only 300AP+ A-Scan/Pachymeter PacScan 300 Plus Features: • High Contrast Color Touch Screen • User Friendly Graphical Interface • 5 Programmable User Profiles • Scan Viewer Archiving Software • USB Interface • SD Memory Card • Built-In Thermal Printer • Storage Compartment • Portable Design Weighing 6 lbs (2.7kg) • Power Requirements: PacScan System: 100-240 VAC; 50/60 Hz Optional Printer: 100-240 VAC; 50/60 Hz |
2. 300A+ A-Scan: Scan Modes: • Direct Contact/Immersion • 5 Examination Modes: Cataract Dense Cataract Aphakic Pseudophakic (5 settings) 4-Gate Manual Measurements: • ACD, Lens, Vitreous, Axial, Average Axial, Standard Deviation • Individual Zone Velocities • Automatic Sensing Algorithm • Measure Review • Auto-Calibration Specifications: • Clinical Accuracy: ±0.10mm • Electrical Accuracy: ±0.023mm • Lens Calculations in 0.25D Increments • 10-Lens Database Formulas: • Refractive: Binkhorst Regression-II Theoretic/T Holladay Hoffer-Q Haigis • Post-Refractive: Latkany Myopic Latkany Hyperopic Aramberri Double-K A-Scan Probe Styles: • Standard A-Scan Probe for Hand-Held, Immersion, or Slit Lamp Mounted Application • Soft-Touch A-Scan Probe for Hand-Held Use Minimizing Corneal Compression |
3. Pachymeter (300AP+): Scan Modes: • Map 1: Single Point, Single-Scan • Map 2: Single Point, Multi-Scan • Map 3: 5 Points, Single-Scan • Map 4: 5 Points, Multi-Scan • CCT, IOP Correction • Calibration Measurements: • Adjustable Corneal Velocity • Automatic Sensing Algorithm • Measure Review • 64 Scans Averaged with Standard Deviation • Internal Accuracy Test • Auto Calibration Specifications: • Range: 125-1000 Microns • Clinical Accuracy: ±5 Microns • Electronic Accuracy: ±1 Microns • 20MHz Direct Contact Probe Pachymeter Probe Styles: • 20 MHz Straight Pachymeter Probe for Use When Patient is in Sitting Position • 20 MHz 45 Degree Angled Pachymeter Probe for Use When Patient is in Supine Position |